Shelly Pro 4CB C10 smart 4-pole circuit breaker, 10 A
Delivery options to:
Choose countryThe Shelly Pro 4CB C10 is a smart 4-pole circuit breaker rated at 10 A, with a C tripping characteristic and 6 kA short-circuit breaking capacity. It protects residential and commercial electrical installations against overloads, short circuits, overvoltage and undervoltage.
Monitoring and automation
- Connectivity: Wi-Fi, Bluetooth and Ethernet, with status checks and remote power disconnection through the Shelly Smart Control app.
- Automation: schedules, scripts, MQTT and webhooks support custom control scenarios.
- Event history: up to 100 records of manual and remote switching and protection trips.
- Local access: a built-in web interface for configuration and parameter monitoring on the local network.
Control and installation
Remote reactivation is possible only after a remote disconnection, not after a protection trip or manual disconnection. A mechanical lever and safety switch allow electronic control to be locked out for maintenance. LEDs indicate connection status, while a mechanical indicator shows contact position.
The breaker mounts on a DIN rail in an electrical panel. It measures 93 × 90 × 76 mm, uses a 230 V AC supply and has an RJ45 Ethernet port.
| Manufacturer | Shelly |
|---|---|
| Model | Pro 4CB C10 |
| Device type | Smart circuit breaker |
| Number of poles | 4 |
| Rated current | 10 A |
| Tripping characteristic | C |
| Rated short-circuit capacity | 6 kA |
| Energy limitation class | 3 |
| Supply voltage | 230 V AC, 50 Hz |
| Minimum operating voltage | 160 V AC, 50 Hz |
| Insulation voltage | 500 V |
| Withstand voltage | 4 kV |
| Power consumption | Less than 3 W |
| Power loss | 4.52 W |
| Protection | Overcurrent, short circuit, overvoltage and undervoltage |
| Voltage measurement | Yes, accuracy ±5% |
| Connectivity | 2.4 GHz Wi-Fi, Bluetooth 4.2, Ethernet |
| Wi-Fi range | Up to 30 m indoors and 50 m outdoors |
| Bluetooth range | Up to 10 m indoors and 30 m outdoors |
| MQTT, webhook and script support | Yes |
| Schedules | Yes |
| Event history | Up to 100 entries |
| Control | Local and remote |
| Mounting | DIN rail |
| Dimensions | 93 × 90 × 76 mm |
| Weight | 575 g |
| Operating temperature | -5 °C to +40 °C |
| Electrical endurance | Over 6 000 cycles |
| Mechanical endurance | Over 10 000 cycles |
| EAN | 3800238074104 |
|---|
Can the breaker be switched back on remotely after a protection trip?
No. Remote reactivation is possible only if the circuit was previously switched off remotely. It is not available after a protection trip or manual disconnection.
Can it be configured on a local network?
Yes. The built-in web interface allows configuration and parameter monitoring directly on the local network.